New Braunfels TX Energy Code Multifamily: 2021 IECC, Local Amendments, and When to Study First
New Braunfels, TX energy code for multifamily: the 2021 IECC with local amendments in Section 14-38, in effect since October 2023, third-party inspection and testing, no R401.2.5 add-on, climate zone 2, and when to study first.
If you are building multifamily inside the City of New Braunfels, Texas, you are on the 2021 International Energy Conservation Code with local amendments. The City Council approved the second and final reading of the ordinance adopting the 2021 International Codes on October 9, 2023, and the City has stated the updated codes took effect on October 23, 2023, replacing the 2018 editions. The energy code lives in Section 14-38 of the New Braunfels Code of Ordinances. That puts New Braunfels with San Antonio, Houston, Dallas, Arlington, Denton, and Grand Prairie on the 2021 IECC, while Austin, Round Rock, College Station, Irving, Frisco, Plano, and McKinney are on the 2024 edition. New Braunfels sits on I-35 between San Antonio and Austin, and teams coming from either city tend to bring the wrong package with them.
This page is the New Braunfels Energy Code door for multifamily developers. For the statewide Texas commercial code path (the 2015 IECC floor, ASHRAE pairings, and why mid-rise is not HERS-first), see ASHRAE COMcheck Texas multifamily. For the Texas study door, see energy code feasibility study Texas. Other Texas city doors already live: Houston Energy Code multifamily, Austin Energy Code multifamily, Dallas Energy Code multifamily, San Antonio Energy Code multifamily, Fort Worth Energy Code multifamily, El Paso Energy Code multifamily, Corpus Christi Energy Code multifamily, Arlington Energy Code multifamily, Plano Energy Code multifamily, McKinney Energy Code multifamily, Frisco Energy Code multifamily, Denton Energy Code multifamily, Irving Energy Code multifamily, Grand Prairie Energy Code multifamily, College Station Energy Code multifamily, and Round Rock Energy Code multifamily. Program, testing, and modeling context: ENERGY STAR Multifamily New Construction, blower door testing for multifamily buildings, and multifamily energy modeling.
What Code Applies in New Braunfels Right Now
Per the City of New Braunfels Building Safety page and the City's adopting ordinance (primary sources; confirm with the City before you file):
- The City's Building Safety page lists the 2021 IBC, IRC, IFC, IEBC, ISPSC, IPMC, IECC, IPC, IMC, and IFGC, plus the 2020 National Electrical Code.
- Legistar file 23-1309 is the second and final reading of the ordinance amending Chapters 14 and 54 to adopt the 2021 International Codes, approved by the City Council on October 9, 2023. The staff memo notes the City was on the 2018 codes and updates its codes every three years.
- In Chapter 14, Article IX of the Code of Ordinances, Section 14-38 adopts the 2021 IECC and the specified appendices, "except as stated in the following amendments."
- The Building Safety page says the City will present the next round of code amendments to the City Council for approval and implementation by the fall of 2027. Until then, plan on the 2021 IECC.
New Braunfels is in Comal and Guadalupe Counties, and the City's own amendment table for the residential R-value alternative is written for climate zone 2, the same zone as San Antonio, Austin, Houston, College Station, and Round Rock, and one zone warmer than Dallas-Fort Worth.
What New Braunfels Changes in the 2021 IECC
Section 14-38 has more teeth than an administrative-only adoption. The residential amendments matter most for garden-style and townhome multifamily:
- No R401.2.5 add-on in the application section (R401.2). The City strikes the reference to Section R401.2.5, the additional energy efficiency requirement, so residential buildings comply with one of the R401.2.1 through R401.2.4 paths. Confirm with the Building Official how this applies to your path before you price additional efficiency packages.
- Ceiling R-38 in the R-value alternative (R402.1.3). The City's climate zone 2 row lists fenestration U-0.40, skylight U-0.65, glazed fenestration SHGC 0.25, ceiling R-38 where the model table shows R-49, wood frame wall R-13 or R-0 plus R-10 continuous, mass wall R-4/6, and floor R-13.
- Third-party insulation inspection, always (R402.4.1.1). The "where required by the code official" language is struck. An approved third party inspects all thermal envelope components, and insulation letters go to the Building Official on a City-approved form after the inspection.
- Third-party air leakage testing, always (R402.4.1.2). Testing is conducted by an approved third party, with the City's text capping leakage at 5.0 air changes per hour or 0.28 CFM per square foot of dwelling unit enclosure area at 50 Pascals, tested to ANSI/RESNET/ICC 380, ASTM E779, or ASTM E1827.
- Outlet boxes sealed, no NEMA OS 4 testing (R402.4.6). Boxes in the thermal envelope still must be sealed, but the NEMA OS 4 test, marking, and installation language is deleted.
- Interior lighting controls apply to apartments (R404.2). The City adds that the dimmer or occupant sensor requirement does not apply to detached one- and two-family dwellings or townhouses. Apartment dwelling units are not on that exempt list.
- Appendices not adopted. Commercial appendices CA (board of appeals), CB (solar-ready zone), and CC (zero energy) and residential appendices RA, RB (solar-ready), and RC (zero energy) are all listed as not adopted.
On the commercial side, the City's amendments only insert the jurisdiction name in C101.1. The 2021 IECC commercial chapter and its ASHRAE 90.1-2019 alternative apply as published.
Residential vs Commercial Split for Multifamily
Because the City did not amend the scope, the 2021 IECC draws the line as published: Group R-2, R-3, and R-4 buildings three stories or less above grade plane fall under the residential provisions, with the City amendments above. Taller apartment buildings, and the nonresidential portions of any building, fall under the commercial provisions, where the 2021 IECC commercial chapter or ASHRAE 90.1-2019 applies.
- Garden-style and townhome projects. Three stories or less usually lands on the residential provisions. Budget the approved third party for both the insulation inspection and the blower door test on every building, plan the lighting controls in the units, and pick the cheapest path among prescriptive, R-value alternative, performance, and ERI.
- Mid-rise, podium, and mixed-use projects. Four stories and up, plus retail, amenity, lobby, corridor, and parking areas, follow commercial documentation, usually a COMcheck or an ASHRAE 90.1-2019 model. The commercial air barrier requirements apply on their own, so price the envelope program early.
Proof From ECC Studies (Method, Not New Braunfels Invoices)
ECC does not publish a New Braunfels or Texas dollar-per-square-foot average, and we do not have a New Braunfels energy-code invoice to present as your number. We cite other studies as proof of method, and we label them that way.
On our 267-unit Cromwell, CT study (CS68), two buildings up to six stories (272,036 square feet) were filed on IECC commercial provisions using ASHRAE 90.1-2019 Appendix G. The recommended all-electric tier came in at about $35.23 per square foot net and captured a $1,500 per unit Energize CT incentive ($400,500). Those are Connecticut outcomes, not New Braunfels invoices. They show the order: lock the path and edition, rank the packages, then document the winner.
On a 112-unit Revere, MA study (CS57), a seven-story mixed-use building kept dwelling units on a Massachusetts Stretch HERS path and still called for a COMcheck report for all common and support areas, plus ASHRAE 62.1 ventilation calculations and lighting power density calculations. The recommended ductless package landed at about $42.52 per square foot net. Those are Massachusetts outcomes. We cite them as proof that mixed-use paperwork splits before modeling hours, not as a New Braunfels price.
Common Mistakes on New Braunfels Multifamily Energy Filings
- Copying an Austin or Round Rock package. Both are on the 2024 IECC. New Braunfels is on the 2021 IECC with its own amendments, so the tables, credits, and ASHRAE year differ.
- Copying a San Antonio package. San Antonio is also on the 2021 IECC in climate zone 2, but its local amendments and submittal bulletins are its own. New Braunfels amendments are in Section 14-38, so read them, not San Antonio's.
- Reusing a 2018 IECC package. New Braunfels enforced the 2018 IECC until the 2021 codes took effect in October 2023. Older REScheck runs and envelope packages need to be redone.
- Assuming the builder can self-test. The City requires an approved third party for both the envelope inspection and the air leakage test on residential-scope buildings. Line up the rater or testing agency before framing.
- Skipping the unit lighting controls. The City's R404.2 amendment exempts only detached one- and two-family dwellings and townhouses, so apartment units need dimmers, occupant sensors, or built-in controls outside the listed exceptions.
- Pairing the wrong ASHRAE year. The 2021 IECC commercial alternative is ASHRAE 90.1-2019, not 90.1-2022.
- Buying COMcheck or ERI hours before the path is locked. The study should settle residential vs commercial, the compliance path, the third-party inspection and testing plan, and the commercial ASHRAE pairing, then the paperwork follows.
When to Study First
Settle the New Braunfels path before anyone buys REScheck, COMcheck, ERI, or whole-building modeling hours:
- Confirm the permit address is inside the City of New Braunfels (not the ETJ, unincorporated Comal or Guadalupe County, or a neighboring city) and on the 2021 IECC under Section 14-38 for your filing date
- Lock the residential vs commercial split (three stories or less for Group R-2 / R-3 / R-4 on the residential provisions, and commercial documentation for nonresidential areas)
- For residential-scope buildings, compare prescriptive, the City's R-value alternative with ceiling R-38, performance, and ERI, and confirm with the Building Official how the struck R401.2.5 reference applies
- Book the approved third party for the insulation inspection, insulation letters, and air leakage test
- For each commercial portion, pick 2021 IECC commercial or ASHRAE 90.1-2019, and model envelope, window, ventilation, and HVAC packages side by side for climate zone 2
- Produce the compliance reports, performance models, and test records against the locked plan
That comparison is what a free feasibility study produces. For the Texas study method, see energy code feasibility study Texas. For how modeling works on apartment buildings in general, see multifamily energy modeling. If the path is already chosen and you need COMchecks, modeling, inspections, or testing, see ECC services.
Bottom Line
The New Braunfels energy code for multifamily is the 2021 IECC with local amendments in Section 14-38, adopted on final reading October 9, 2023 and in effect since October 23, 2023, replacing the 2018 IECC. The City requires an approved third party for residential insulation inspection and air leakage testing, strikes the R401.2.5 reference in R401.2, lists ceiling R-38 in its climate zone 2 R-value alternative, drops NEMA OS 4 box testing, keeps unit lighting controls for apartments, and adopts none of the IECC appendices. The commercial side, with ASHRAE 90.1-2019 as the alternative, applies as published. This is the New Braunfels city-code door, not the statewide Texas code-path page, not the other Texas city doors, and not the Texas study door. Lock the split, the path, and the third-party plan first, then buy the paperwork that matches the plan.